Installation/Datafile Fixes
New MMC-D32/D64 ETX Card Support for PiCPro V16.X and V17.X
If you are using PiCPro V16.0, V16.1 or V17.0 (any service pack level) with an MMC-D32 (P/Ns M.3000.0816 & M.3000.1064) or an MMC-D64 (P/N M.3000.0817), these controls must use the firmware provided below.
Note: MMC-D32 and MMC-D64 controls with other Part Numbers are not affected by this requirement.
Filename |
Description |
|
PRODUCT: Firmware support for MMC-D32 (P/Ns M.3000.0816 & M.3000.1064) or an MMC-D64 (P/N M.3000.0817).
FIX: Download and unzip .hex file. Copy hex file over to:
V16.X: C:\Program Files\G&L Motion Control\PiCPro V16.0 Professional Edition\Firmware\Digital MMC Smart Drive
V17.X:
C:\G&L Motion Control Data\PiCPro V17.0 Professional Edition\Firmware\Digital MMC Smart Drive
Note: The drive letter above (C:) may be different on your installation.
Released 03/26/2010, 187 KB |
PiCPro and PowerX hardware support
To support PowerX hardware, older versions of PiCPro (prior to V15.1SP1) have to be updated with new drive firmware and an accompanying parameter (.CSV) file.
Supported Versions and
Download Filename
|
Description |
ANALOG DRIVE
POWERX
SUPPORT
PiCPro Version:
V14.1,
V14.1SP1,
V15.0,
V15.1,
V15.1SP1
Firmware Version:
2.0, 2.01, 2.02,
2.03,
2.04, 2.05
AnalogPowerX.zip |
ERROR: Control Response: Hex file too old for hardware.
FIX: Download the extract file contents. Zip file contains V2.06 analog firmware and a two new parameter CSV files.
Copy the parameter CSV files to:
PiCProInstallDir / Personalities
Copy the firmware file to:
PiCProInstallDir / Firmware / Analog MMC Smart Drive
for V15.X PiCPro and to
PiCProInstallDir / Firmware
for V14.X PiCPro
Re-release 09/04/2008, 66 KB (add new motor csv file)
|
|
ERROR: Control Response: Hex file too old for hardware.
FIX: Download and unzip file contents. Zip file contains V2.05 digital firmware and a new parameter CSV file.
Copy the parameter CSV file to:
PiCProInstallDir / Personalities
Copy the firmware file to:
PiCProInstallDir / Firmware / Digital MMC Smart Drive
Released 1/16/2007, 71 KB
|
|
ERROR: Control Response: Hex file too old for hardware.
FIX: Download and unzip file contents. Zip file contains V4.10 digital firmware and a new parameter CSV file.
Copy the parameter CSV file to:
PiCProInstallDir / Personalities
Copy the firmware file to:
PiCProInstallDir / Firmware / Digital MMC Smart Drive
Released 1/16/2007, 79 KB
|
Other fixes
Filename |
Description |
|
ERROR: Any of the following...
- Unable to create a custom motor with a rated voltage of 480.
- Unable to paste motor data for a motor with a rated voltage of 480.
- Unable to download file data for a motor with a rated voltage of 480.
PRODUCT: Paramdef.csv and digitalparamdef.csv replacement files for PiCPro V15.1.
FIX: Download and unzip .csv files. Replace file of same name under C:\Program Files\G&L Motion Control\PiCPro V15.1 Professional Edition\Personalities
Released 01/23/2006, 22 KB |
|
ERROR:
Communication failure if p-gain is set to zero OR
Feedback type ENDAT will not maintain absolute position value through a power cycle.
PRODUCT: R0400 Digital MMC Smart Drive Firmware replacement for PiCPro V15.1.
FIX: Download and unzip .hex file. Replace file of same name under C:\Program Files\G&L Motion Control\PiCPro V15.1 Professional Edition\Firmware\Digital MMC Smart Drive
Released 01/12/2006, 67 KB
|
|
ERROR: Communication failure if p-gain is set to zero.
PRODUCT: R0400 Digital MMC Smart Drive Firmware replacement for PiCPro V15.1.
FIX: Download and unzip .hex file. Replace file of same name under C:\Program Files\G&L Motion Control\PiCPro V15.1 Professional Edition\Firmware\Digital MMC Smart Drive
Released 11/16/2005, 67 KB
|
|
ERROR: PiCPro auto-update fails to connect to update site. This began to fail 12/13/2004 because the location of the Service Pack website has moved to a new server.
PRODUCT: All editions of PiCPro - V13, V14, V14.1 with or without a service pack applied.
FIX: You need to run this program to modify the location of the old Service Pack server to the new Service Pack server. This program should be run again anytime a full version of PiCPro is installed or a service pack is installed.
Released 12/15/2004, 257 KB |
|
ERROR: "Unknown Error 259"
PRODUCT: MMC for PC Support Software on W2000
FIX: Uninstall the incomplete MMC for PC support software. Download and install the new version of MMC for PC support software V2.1.
Released 10/22/2003, 669 KB |
|
ERROR: "The MSVCRT.DLL file is linked to missing export NTDLL.DLL:Rtl...
PRODUCT: PiCPro for Windows (any) on W95/98
FIX: Download the replacement library file - instructions are included in the download.
Released 10/20/2003, 130KB |
|